Fridge temperature log, properly.

How often to check, what bands to set, when to fail an entry, what corrective action looks like. The food-safety record the EHO opens first — and the one that lets you defend an FHRS-5 with a single export.

The rules

UK fridge temperature standards.

Food law (Regulation 853/2004 retained, plus the Food Safety and Hygiene (England) Regulations 2013 and equivalent in Wales, Scotland and NI) sets the maximum chilled-food storage temperature at 8°C. Best-practice operational targets sit well below that.

Legal maximum (chilled)

8°C — the statutory limit for chilled food storage. Above this is a food-safety offence.

Operational target (chilled)

0–5°C — the band most kitchens log against. Gives a 3°C buffer before any legal issue.

Freezer target

-18°C or colder — for frozen storage. Above -15°C should trigger corrective action.

Hot-hold minimum

63°C or above — for any hot-held cooked food. Below this and time-temperature controls apply.

The frequency

How often you actually need to log.

"Daily" satisfies the FSA's Safer Food Better Business pack. Twice daily satisfies most EHOs. Three times a day satisfies the inspector who's seen the kitchen before.

Opening check (every day).

First thing in. Reads taken before any door-opening that might've affected the cabinet. Catches overnight failures.

Mid-service check (busy kitchens).

Mid-lunch or mid-dinner. Catches the fridge that's struggling because the door's been open too long during prep.

Closing check (every day).

Last thing out. Confirms the cabinet's been steady all day; gives you the last reading before any overnight risk.

Probe calibration (weekly).

Boil/ice test on the digital probe, recorded against the calibration log. Drift invalidates the readings — calibration is the proof the readings are real.

The failure

What to do when the reading fails.

Step 1 · Record the failure.

Don't retry. Don't "just take another reading". The first read is the real read. Log it as a fail.

Step 2 · Identify the stock.

What was in the cabinet? When was it last known good? Use last-known-good plus time-temp combination to decide discard vs use.

Step 3 · Take corrective action.

Move stock to a working fridge. Discard time-temperature-abused product. Call the engineer. Whatever the action is, it's logged.

Step 4 · Retest and document.

Once the cabinet is working again — new reading, taken at intervals, logged. The audit trail closes the loop on the failure.

Why this matters more than the reading itself.

The EHO knows fridges fail. What separates a 5 from a 3 is whether you spotted, recorded and acted on the failure. The audit trail is the evidence.

How Hospitality App does it

The fridge log, but it can't lie.

Per-cabinet min/max bands. Reading above band? App marks the entry FAIL and prompts corrective action. Photo evidence required for the discard log. Calibration log built in. Tap export, send the EHO the last 12 months as a CSV.

Start free trial For restaurants
FAQ

Fridge temperature logs, asked & answered.

How often should you record fridge temperatures?

Twice a day is the practical UK standard — opening and closing. Busy kitchens add a midday check.

What temperature should a commercial fridge be?

UK law requires ≤8°C; operational target is 0–5°C. Freezers run at -18°C or colder.

What do you do if a fridge reads over temperature?

Record the failed reading, take corrective action (move stock, discard, call engineer), retest. The audit trail of the failure is what the EHO wants.